Combotreat Pwd Boiler Treatment Compound
RXSOL-50-5004-025 is a dry powder containing Alkalinity builders, Phosphates and Sludge Conditioners.
RXSOL-50-5004-025 is a well-balanced blend of several powder for boiler water treatment, resulting in a scale and corrosion control by one simple operation.
Application
The correct level of alkalinity ensures that optimum conditions exist for :
Precipitation of hardness salts in conjunction with phosphate.
Neutralization of acidic conditions. Avoidance of caustic corrosion.
Control of magnesium and calcium salts.
Control of hardness.
RXSOL-50-5004-025 provides a phosphate reserve to effectively react with and precipitate the hardness salts introduced with the feed water.
selected BOILER COMPOUND FOR LOW PRESSURE STEAM BOILER.
Dosage
RXSOL-50-5004-025 is best dosed by means of a bypass pot feeder directly into the boiler feed line
Funtion Mechanism:-
Alkalinity Control:-This components of RXSOL-50-5004-025 chemically precipitate the hardness of salts like Calcium & Magnesium & neutralizes the acidic conditions.
Hardness Control:-RXSOL-50-5004-025 provides phosphate reserve to effectively react with and precipitate the hardness salts introduces with the feed water.
Sludge Conditioner:-RXSOL-50-5004-025 component will preventing the sludge from adhering to metals surfaces. Boiler sludge can only be removed by blow down.
Oxygen Scavanger:-Catalyzed of RXSOL-50-5004-025 controls the formation of oxygen to protects boiler & steam line corrosion protection. As an additional benefits it will assist to neutralize dissolved carbon dioxide. In this way RXSOL-50-5004-025 preventing oxygen “Pitting” corrosion.
Applications, Dosage:-RXSOL-50-5004-025 is strongly alkaline. RXSOL-50-5004-025 is best applied diluted with WATER , any convenient strength on a continuous basis using a suitable chemicals pump . The product should be applied to the boiler feed tank or feed line to ensure adequate mixing. The dosage rate of RXSOL-50-5004-025 is dependent on boiler operating condition, Feed 1 Kg of RXSOL-50-5004-025 solution for per thousand Ltr of boilers water Then control the system by Periodic Alkalinity test procedure. If p-Alkalinity is below 200 ppm increase the ratio of RXSOL-50-5004-025 solution. If p-Alkalinity is above 400 ppm reduce the concentration of
RXSOL-50-5004-COMB solution by dilution with water.
Control Procedure:-Control is by simple boiler water tests or RX CLEANSERS can provide a suitable test kits for this purpose
Technical Specifications
Properties:-
|
Appearance |
White Powder |
|
Solubility In Water |
Complete |
|
pH (1 Vol %) |
13 |
|
Compability |
|
|
Rubber |
No known effect. |
|
Packaging |
Product Size (in Kg ) |