How to Clean and maintain Oil Side of Heat Exchangers?

Very Simple to clean and maintain Oil Side of Heat Exchanger, 1st step is remove all excess oil from Heat Excahanger, Then make arrangement to re-circulate the cleaning solution through heat exchanger. 

USE RXSOL Carbon Remover Cleaner in circulatory drum, which is connected for circulation. For complete dissolving of Oily carbonecious deposits from Heat Exchanger continue circulation 10-12 Hrs, Then after full cleaning operation and removal of deposits drain out the solution and use high pressure water pressure and continiue till clear water come out. Then Finally DRY out the Heat Exchanger.
 
NOTE : To enhance the cleaning or reducing circualtion time (down time ) Solution can be heated upto 30-40 °C throughout the cleaning operation